Find the most up-to-date version of EN at Engineering Buy EN TEMPORARY WORKS EQUIPMENT – PART 1: SCAFFOLDS – PERFORMANCE REQUIREMENTS AND GENERAL DESIGN from SAI. Specifies performance requirements and methods of structural and general design for access and working scaffolds. Requirements given are for scaffold.
Author: | Dikasa Babei |
Country: | Guinea-Bissau |
Language: | English (Spanish) |
Genre: | Automotive |
Published (Last): | 19 October 2008 |
Pages: | 442 |
PDF File Size: | 16.66 Mb |
ePub File Size: | 10.50 Mb |
ISBN: | 848-1-15013-598-5 |
Downloads: | 80751 |
Price: | Free* [*Free Regsitration Required] |
Uploader: | Tozshura |
Document Status Indicators The Green document status indicator indicates that the document is: In the case a 2D or 3D CAD model of the scaffold is available, this is enn imported as an analysis model.
SCIA Engineer uses a stability analysis to determine the buckling shapes of the scaffold, which in turn are used as imperfections for the full second order analysis. Customers who bought this product also bought BS EN Requirements given are for scaffold structures that rely on the adjacent structures for stability. If specific test results for the diagonals of modular systems are available, the stiffness derived from the tests is accounted for using a translation spring.
Specifies performance requirements and methods of structural and general design for access and working scaffolds.
In SCIA Engineer the determination of system lengths and buckling lengths beyond a node with a flexible hinge is different from the standard solution where the system and 12811-1 lengths are determined by the flexible hinge and will be cut at the level with the hinged node. The Red document status indicator indicates that the document is an old version The document has likely been withdrawn by the publisher, also the meta data presented here may be out of date as it is no longer being maintained by the editorial teams at NBS.
Leistungsanforderungen, Entwurf, Konstruktion und Bemessung. In most cases, the base jacks are not fixed to the ground.
SCIA Scaffolding allows for an accurate modelling of different scaffolding components including their appropriate specifics. Fn is to be used in conjunction with the Eurocodes for structural design.
Worldwide Standards We can source any standard from anywhere in the world. Find Similar Items This product falls into the following categories. Click to learn more.
The advantage of using templates is that all common data e. Search all products by. Specific checks according to EN and EN Exigences de performance et etude, en general Title in German Temporaere Konstruktionen fuer Bauwerke.
Integrates complete modelling, analysis and drawings. Structural systems, Occupational safety, Scaffolding components, Scaffolds, Wind loading, Design calculations, Safety measures, Structural design, Performance, Facades, Construction equipment, Temporary structures, Loading. Want access to British Standards?
The Eurocode steel code check has been extended for the design of scaffolding projects. 21811-1 there may be more recent versions of the document. Their committees work with the manufacturing and service industries, government, businesses and consumers to facilitate the production of British, European and International standards.
Templates save a lot of effort as they may have predefined all required load cases and combinations.
Modular systems are defined as systems in which the transoms and standards are separate components. 128811-1 European Standard includes rules for structural design, which are of particular relevance to scaffolds made of certain materials. In addition, any pre-prepared User Blocks, i. Equipements temporaires de chantiers. Full integration in the main graphical user interface. The user chooses what best meets their current needs.
This rn modelled using friction supports. SCIA Scaffolding offers different approaches for modelling of different types of scaffold. SCIA Scaffolding integrates an extensive library of couplers which contains the different types given in Annex C to EN including their stiffness.
In the ultimate limit state, the scaffold members are checked according to the capacity check defined in EN This document sets out performance requirements for working scaffolds. The user can also add their own couplers in this open library.
One of the main advantages is a short erection time.
The standards provide facilities at pre- defined modular intervals for the connection of the other scaffold components. In addition to the specific scaffolding checks, full design and check of the structure according to EN is also available for those scaffolds which do not meet the EN prerequisites.
Engineers who deal with the design of scaffolds regularly will definitely welcome the possibility to prepare tailor-made templates for all types of scaffolds they have to handle.
A separate module [see esadt. See national foreword on future corrections to be made. We use cookies to make our website easier to use and to better understand your needs. In addition to the eccentricity, a special behaviour of diagonals in modular systems is that they mostly have a small gap along their length, caused by a slight margin between the pen and hole.
Click here to find 112811-1 how to access this document. All standard modelling and manipulation copy, move, mirror, etc. Performance requirements and general design Status: If wooden planks are used, however, the stiffness of the planks cannot be accounted for since the planks are put loose on the transoms.
Their main advantage is their versatility.